Operating your water heater, Lighting instructions, Explosion hazard – Kenmore 153.339432 User Manual
Page 23: Replace view port if glass is missing or damaged, For your safety read before lighting, Manual, To turn off gas to appliance, Installation instructions -15, Operating your water heater -25, Awarning
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/665502/23/background.png)
OPERATING YOUR WATER HEATER
Lighting Instructions
Read
and
understand
these
directions
thoroughly
before
attempting to light or re-light the pilot. Make sure the view port
is not missing or damaged. (See Figure 32.) Make sure the
tank is completely filled with water before lighting the pilot.
Check the rating plate near the gas control valve/thermostat for
the correct gas. Do not use this water heater with any gas other
than the one listed on the rating plate. If you have any questions
or doubts, consult your gas supplier or gas utility company.
U/
AWARNING
Explosion Hazard
Replace view port if glass is missing
or damaged.
Failure to do so can result in death,
explosion or fire.
FOR YOUR SAFETY READ BEFORE LIGHTING
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES
A. This appliance has a pilot which is lit by a piezo
electric spark gas ignition system. Do not open
the inner door of the appliance and tryTo light
the pilot by hand.
B. BEFORE LIGHTINGsmell all around the appliance
C.Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
area for gas. Be sure to smell next to'the floor D. Do not use this appliance if any part has been under
because some gas is heavier than air and
will water. Immediately contact a qualihed installer or
settle on the floor
service agency to replace a flooded water heater.
WHAT TO DO IF YOU SMELL GAS
D° not attempt to repair the unit! It must be replaced!
Do not try to light any appliance.
E. DO NOT USE THIS APPLIANCE IF THERE HAS
• Do not touch any electric switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
BEEN AN IGNITION OF VAPORS. Immediately
call a qualified service technician to inspect the
appliance. Water heaters subjected to a
flammable vapors ignition will show a
discoloration on the air intake grid and require
replacement of the entire water heater.
LIGHTING INSTRUCTIONS
MAIN BURNER
PILOT
THERMOCOUPLE
FIGURE "D"
STOP!
Read the safety
above on this label.
2.Set the thermostat to lowest setting(PILOT LIGHTING)
Turn thermostat dial fully clockwise c until it stops.
3. Push the gas control knob down slightly and turn
clockwise C to "OFF". SEE FIGURE 'A'.
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed down slightly. Do not force.
4. Remove the outer burner door located below
the gas control.
5. Wait ten (10) minutes to clear out any gas. If you
then smell gas,^rfBWk STOP! Follow "B" in the
safety information I B./1 above on this label. If
you don't smell gas, ^S#ao to next step.
6. This unit is equipped with a push button pilot ignitor,
which is used to light the pilot. Locate the ignitor
on the gas control.
7. Turn gas control knob counterclockwise
t) to ^PILOT". SEE FIGURE 'B'.
8. The pilot is located on the left side of the burner. It
can be located by looking through the glass view port
while pressing the piezo ignitor button several times.
Look for a spark at the pilot location, Figure "D".
Once the pilot has been found, push the gas knob
all the way down. Immediately press the pilot ignitor
button rapidly (4) to (5) times. If the pilot will not
light, repeat step (3) through (9).
10. Continue to hold the gas control knob down for about
one (1) minute after the pilot is lit. Release the gas
control knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat step (3) through (9). It
may take several minutes for air to clear the lines
before the pilot will light.
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries,
turn the gas control knob clockwise to 'OFF and
call your service technician or gas supplier.
SEE FIGURE 'A'
11. Once the pilot flame is established replace the
outer burner door.
12. At arm's length away, turn gas control knob
counterclockwise "D to 'ON'. SEE FIGURE 'C'.
13. Set thermostat to desired setting.
Hotter
water Increases the risk of
manual
^ scald injury. Consult the instruction
lal before changing temperature.
TO TURN OFF GAS TO APPLIANCE
I.Set the thermostat to
(PILOT LIGHTING).
owest setting 2. Push gas control knob down slightly and turn clock
wise C to 'OFF'. Do not force. SEE FIGURE 'A'.
23