for purchasing a Sears water hearer.
Properly installed and maintained, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears call the local Sears
Service Center or any Sears store. They will arrange for prompt,
quality installation by Sears authorized contractors.
Abbreviations Found In Tbis Instruction Manual
C.S.A. - Canadian Standards Association
A.N.S.I. - American National Standards Institute
N.F.P.A. - National Fire Protection Agency
A WARNING
This gas-fired water heater is design certified by CSA
INTERNATIONAL
under
American
National
Standard/CSA
Standard
for
Gas
Water
Heaters
ANS
Z21.10.1 • CSA 4.1 (latest edition). The installation must
conform with this manual, Local Codes and with the latest
edition of the National Fuel Gas Code, ANSI Z223.I.
This publication is available from your local government or
public
library,
gas
company,
or
by
writing
NFPA,
Batterymarch Park, Quincy, MA 02269.
Read the “Safety Precautions” section, pages 2 through 4 of
this manual first and then the entire manual carefully. If you
don’t follow the safety rules, the water heater will not operate
properly. It could cause DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera
tion, and maintenance of the gas-fired water heater. It also
contains warnings through out the manual that you must read
and be aware of. All warnings and all instructions are essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, RFAD
THE ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; ps company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition of the National
Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54.
This publication is available from your local government or
public library or gas company or by writing NFPA,
Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe instal
lation are very important in preventing death from possible
carbon monoxide poisoning and fires.
Examine the location to ensure the water heater complies with
the “Facts to Consider about the Location” section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce
dures. Instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
Product Specifications
MODEL
NUMBER
TANK
CAPACITY
IN GALLONS
TYPE
OF
GAS
B.T.U.
RATE
RECOVERY RATE
GALS. PER HOUR
RISE
MINIMUM
VENT
PIPE
DIMENSIONS IN INCHES
DIAMETER
HEIGHT TO
JACKET TOP
153.330402
40
NATURAL
40,000
46.0
3” or 4"
18"
60"
153.330452
40
NATURAL
40,000
46.0
3” or 4”
18"
60"
153.330502
50
NATURAL
40,000
46.0
3” or 4"
20"
59Z"
153.330552
50
NATURAL
40,000
46.0
3" or
4"
20"
59/T
153.330702
75
NATURAL
55,000
59.2
4"
24"
60"
153.330752
75
NATURAL
55,000
59.2
4"
24”
60"