Installation Instructions (cont’d)
USE WITHOUT POWER CORD (cont’d)
3. A standard //' conduit opening has been made in the water
heater junction box for the conduit connection.
4. Use wire nuts and connect the power supply wiring to the
wires inside the water heater’s junction box.
5. The water heater must be electrically “grounded” by the
installer. A green ground screw has been provided on the
water heater’s junction box. Connect ground wire to this
location. For complete grounding details and all allowable
exceptions, refer to local codes or in the absence of local
codes, with the latest edition of the National Electrical Code,
ANSI/NFPA 70.
6. Replace the wiring junction cover using the screw
provided.
WIRING DIAGRAM
Venting
AWARNING
AWARNING
lb insure proper venting of this gas-fired water heater, the cor
rect vent pipe diameter must be utilized. Any additions of
other gas appliances on vent with this water heater will
adversely affect the operation of the water heater.
The vent pipe from the water heater must be 3" diameter
PVC schedule 40 pipe and must slope upward 1/4 inch per
linear foot.
The combustion and ventilation air flow must not be obstructed.
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
A WARNING
The water heater with draft hood installed must be properly
vented to a chimney which terminates outdoors. Never oper<
ate the water heater unless it is vented to the outdoors and has
adequate air supply to avoid risks of improper operation, explo
sion or asphyxiation.
MIN. RISE 1/4"
PER FOOT
AWARNING
AWARNING
Obstructed or deteriorated vent systems may present a serious
health risk or asphyxiation.
Failure to have required clearances between water heater and
combustible material will result in a fire hazard.
15