6. Position the new thermocouple through the bottom opening

of the two piece wire connector (Figure 34). Be sure igniter

wire is positioned through the small opening of the two

piece wire connector.

7. Re-attach the burner. Note the orientation of the burner

(Figure 33.)

8. See “Replacing the Manifold/Burner Assembly.”

MANiFOL

FIGURE 35.

Replacing the Pilot/ Pilot Tube Assembly

1. Remove the manifold/burner assembly. See “Removing

the Manifold/Burner Assembly.”

2. Lift the retainer clip straight up from the back of the two

piece wire connector (using a flat-blade screwdriver), then

remove the two piece wire connector from the manifold

door (Figure 34.)

IMPORTANT: Be careful not to bend or alter the position of the

pilot tube. It will be used as a bending template for the new

pilot assembly.
3. Take off the burner by removing the two (2) screws located

underneath the burner. See Figure 33.

4. Remove and keep the screw securing the pilot assembly to

the pilot bracket. (Figure 36)

5. Remove and keep the old pilot/pilot tube assembly.
6. Using the old pilot/pilot tube assembly as a guide, bend

the new pilot tube and new thermocouple to match the

old ones. NOTE: Make only the bends closest to the pilot

before going to the next step. (Figure 36)

OLD PILOT ASSEMBLY

PILOT TUBE

OTHER FITTINGS
NOT SHOWN
FOR CLARITY

IGNITER WIRE

THERMOCOUPLE

FIRST BEND(S)

8

7. Route the new pilot tube, thermocouple, and igniter wire

through the manifold/burner door opening. (Figure 34)

Re-attach the pilot assembly to the pilot bracket and secure

using the screw removed earlier.
Position the new pilot tube through the largest opening of

the two piece wire connector. NOTE: The largest opening

should be located at the top position. The igniter wire

should be located in the middle opening and thermocouple

in the bottom opening. (Figure 37)

FIGURE 37.

10. Reposition the two piece wire connector in the manifold

door opening and secure it with the retainer clip.

11. Carefully bend the new pilot tube and thermocouple to

match the bend of the manifold tube. NOTE: When bending,

DO NOT crimp or crease the pilot tube or thermocouple.

(Figure 34)

12. Before you proceed to the next step, install the new brass

ferrule nut in the gas control valve/thermostat’s pilot tube

opening. HAND TIGHTEN ONLY.

13. See “Replacing the Manifold/Burner Assembly.”

Cleaning the Combustion Chamber and

Flame-arrestor____________________________

1. Follow procedure outlined in “Removing the Manifold/

Burner Assembly.”

2. Use a vacuum cleaner/shop vac to remove all loose debris

in the combustion chamber (Figure 38). Use compressed

air to clear any dust or debris that may have accumulated

in the flame-arrestor.

COMBUSTION CHAMBER

FLAME ARRESTOR

DOOR GASKET

FIGURE 36.

FIGURE 38.

Reassemble by following the procedure under “Replacing

the Manifold/Burner Assembly.”