beautypg.com

Controls and features, Generator panel – Champion Power Equipment 76555 User Manual

Page 10

background image

7

REV 76555-20140718

ENGLISH

76555

Generator Panel

1

2

3

4

5

7

6

8

(1) Fuel Selector Switch – Used to select and turn on

gas or LPG fuel source.

(2) Ignition Switch – Used to start or stop the

generator.

(3) Intelligauge – Three mode digital meter for

displaying running hours, voltage and hertz.

(4) Battery Switch – Enables/disables starting

electrically.

(5) LPG Hose Connector – Used to connect LPG hose

to generator.

(6) Ground Terminal – Consult an electrician for local

grounding regulations.

(7) Circuit Breakers

(8) 120 Volt AC, 30 Amp Twist-Lock Receptacle

(NEMA L5-30R) –

May be used to supply electrical

power for the operation of 120 Volt AC, 30 Amp,
single phase 60 Hz electrical loads.

(9) 120 Volt AC, 20 Amp Duplex (2)

(NEMA 5-20R) –

May be used to supply electrical

power for the operation of 120 Volt AC, 20 Amp,
single phase 60 Hz electrical loads.

CONTROLS AND FEATURES

9