Controls and features, Power panel, Parts included – Champion Power Equipment 100157 User Manual
Page 9

6
100157
ENGLISH
Power Panel
3
CONTROLS AND fEATURES
1
2
6
4
(1) Engine Switch – Used to turn the generator on and
off.
(2) Intelligauge – Three mode digital meter for displaying
running hours, voltage and hertz.
(3) Circuit Breakers – Protects the generator against
electrical overloads. Push to reset breaker.
(4) Ground Terminal – Consult an electrician for local
grounding regulations.
(5) 120 Volt AC, 30 Amp Twist-Lock Receptacle (NEMA
L5-30R) – May be used to supply electrical power
for the operation of 120 Volt AC, single phase 60 Hz
electrical loads.
(6) 120 Volt AC, 30 Amp Receptacle (NEMA TT-
30R)
– May be used to supply electrical power for
the operation of 120 Volt AC, single phase 60 Hz
electrical loads.
(7) 120 Volt AC, 20 Amp Duplex
(GFCI 5-20R) – May be used to supply electrical
power for the operation of 120 Volt AC, single phase
60 Hz electrical loads.
5
7
Parts Included
Your 100157 Gasoline Powered Generator ships with the
following parts:
Wheel Kit
– 8 in. Wheel
2
– Flange Bolt (M10x105 for Wheel)
2
– Bushing
2
– Flat Washer
Ø
10
2
– Lock Nut (M10)
2
– Support Leg (w/vibration mounts)
1
– Flange Bolt (M8x16 for Support Leg)
2
– Handle
1
– Flange Bolt (M8x45 for Handle)
2
– Flange Lock Nut (M8)
4
Other
– Oil Funnel
1
– Oil
0.6 qt. (0.6 L)