Specifications, Engine specifications, Generator specifications – Champion Power Equipment 41030 User Manual
Page 19: Maintenance valve clearance, Spark plugs, Fuel, An important message about temperature

REV 41030-20130517
16
41030
ENGLISH
SPECIfICATIONS
Engine Specifications
– Model
180F
– Displacement
292cc
– Type
4-Stroke OHV
– Start Type
Recoil
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 1.16 qt. (1.1 L).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
Generator Specifications
– Model
41030
– Rated Wattage
5000 Watts
– Starting Wattage
6250 Watts
– AC Load
120/240 V
– Phase
Single
– Frequency
60 Hz
– Fuel Capacity
5.7 gallons (21.5 L)
– Gross Weight
165.6 lbs (75.1 kg)
– Net Weight
146.8 lbs (66.6 kg)
– Height
24.9 inches (63.2 cm)
– Width
25.7 inches (65.4 cm)
– Length
30.1 inches (76.5 cm)
Maintenance valve Clearance
– Intake: 0.10 – 0.15 mm (0.004 – 0.006 in.)
– Exhaust: 0.15 – 0.20 mm (0.006 – 0.008 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.
Spark Plugs
OEM spark plug: NHSP F6RTC
Replacement spark plug: NGK BPR6ES or equivalent
Make certain the spark plug gap is 0.6 - 0.8 mm or
(0.024 - 0.031 in.).
fuel
Fuel capacity is 5.7 gallons (21.5 L). Use regular
unleaded gasoline with a minimum octane rating of 85
and an ethanol content of less than 10% by volume.
An Important Message About Temperature
Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures
ranging from -15°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures
outside this range during storage, it should be brought
back within this range before operation. In any event,
the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and
other vents.