Generator Panel
1
2
3
4
5
7
6
8
10
(1) Fuel Selector Switch – Used to select and turn on
gas or LPG fuel source.
(2) Ignition Switch – Used to start or stop the
generator.
(3) Intelligauge – Three mode digital meter for
displaying running hours, voltage and hertz.
(4) Battery Switch – Enables/disables starting
electrically.
(5) LPG Hose Connector – Used to connect LPG hose
to generator.
(6) Ground Terminal – Consult an electrician for local
grounding regulations.
(7) 120 volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L5-30R) –
May be used to supply electrical
power for the operation of 120 Volt AC, 30 Amp,
single phase 60 Hz electrical loads.
(8) 120/240 volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L14-30R) –
May be used to supply
electrical power for the operation of 120
and/or 240 Volt AC, 30 Amp, single phase 60 Hz
electrical loads.
(9) 120 volt AC, 20 Amp Duplex (2)
(NEMA 5-20R) –
May be used to supply electrical
power for the operation of 120 Volt AC, 20 Amp,
single phase 60 Hz electrical loads.
(10) Circuit Breakers