OPERATION

Starting the Engine

1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator.

Never start or stop the generator with electrical
devices plugged in or turned on.

3. Turn the fuel valve to the “ON” position.
4. Flip the ignition switch to the “ON” position.
5. Move the choke lever to the “CHOKE” position.
6. ELECTRIC START: Press and hold the ignition switch

to the “START” position. Release as the engine begins
to start. If the engine fails to start within five seconds,
release the switch and wait at least ten seconds before
attempting to start the engine again.

7. RECOIL START: Pull the starter cord slowly until

resistance is felt and then pull rapidly

8. Do not over-choke. As as soon as engine starts, move

the choke lever to the “RUN” position.

Surge Protection

Electronic devices, including computers and many
programmable appliances use components that are
designed to operate within a narrow voltage range and
may be affected by momentary voltage fluctuations.
While there is no way to prevent voltage fluctuations, you
can take steps to protect sensitive electronic equipment.
1. Install UL1449, CSA-listed, plug-in surge suppressors

on the outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually
all short-duration voltage fluctuations.

Voltage fluctuation may impair the proper
functioning of sensitive electronic equipment.

CAUTION

Generator Location

NEVER operate the generator inside any building,
including garages, basements, crawlspaces and
sheds, or any enclosure or compartment, including the
generator compartment of a recreational vehicle. Please
consult your local authority. In some areas, generators
must be registered with the local utility. Generators
used at construction sites may be subject to additional
rules and regulations. Generators should be on a flat,
level surface at all times. (Even while not in operation)
Generators must have at least 1.5 m (5 ft.) of clearance
from all combustible material. In addition to clearance
from all combustible material, generators must also
have at least 91.4 cm (3 ft.) of clearance on all sides to
allow for adequate cooling, maintenance and servicing.
Generators should never be started or operated in the
back of a SUV, camper, trailer, in the bed of a truck
(regular, flat or otherwise), under staircases/stairwells,
next to walls or buildings, or in any other location that
will not allow for adequate cooling of the generator
and/or the muffler. DO NOT contain generators during
operation. Allow generators to properly cool before
transport or storage.
Place the generator in a well-ventilated area. DO NOT
place the generator near vents or intakes where exhaust
fumes could be drawn into occupied or confined
spaces. Carefully consider wind and air currents when
positioning generator.
Failure to follow proper safety precautions may void
manufacturer’s warranty.

Do not operate or store the generator in rain, snow,
or wet weather.

Using a generator or electrical appliance in wet
conditions, such as rain or snow, or near a pool or
sprinkler system, or when your hands are wet, could
result in electrocution.

WARNING

WARNING

During operation the muffler and exhaust fumes
produced will become hot. If adequate cooling and
breathing space are not supplied, or if the generator
is blocked or contained, it can become extremely
heated and may lead to fire.

Grounding

The generator system ground connects the frame to the
ground terminals on the power panel. The system ground is
connected to the AC neutral wire.