beautypg.com

Braeburn 162025 User Manual

Installation instructions, Typical installations, Media air cleaner

background image

162025

MEDIA

AIR CLEANER

INSTALLATION INSTRUCTIONS

HIGH BOY

COUNTER-FLOW

RETURN AIR

RETURN AIR

WARM AIR

WARM AIR

WARM AIR

BRAEBURN

®

MEDIA AIR CLEANER

IMPORTANT: A 26 INCH CLEARANCE MUST BE ALLOWED FOR REMOVAL OF THE MEDIA CARTRIDGE

FROM THE CABINET.

LOW BOY

RETURN AIR

WARM AIR

BRAEBURN

®

FLOW THROUGH

HUMIDIFIER

7

22

25

18

20 1/4

26 1/8

21 5/16

1. Turn off electricity to furnace.
2. Remove front cover.
3. Slide media cartridge from air cleaner cabinet, and discard packing material.
4. Remove and discard existing furnace air filter.
5. Install cabinet in return air system. Duct supports are recommended to support weight of cabinet. See typical installations.
6. Slide the media cartridge into the cabinet. Be sure the airflow arrow on the cartridge is pointing towards the furnace

blower. The wire mesh is always on the downstream side of the filter media. Replace cover.
7. If the optional air filter gauge accessory (model 169000) is to be used, install on a vertical duct surface between

the air cleaner and the furnace blower.
8. Turn on electricity and furnace and check performance of all equipment.

This air cleaner is designed for use in systems up to

2000 CFM. For higher airflows additional units may

be required.

FOR INSTALLATION IN THE RETURN AIR DUCT OF ANY FORCED AIR HEATING AND COOLING SYSTEM

INSTALLER: LEAVE THESE INSTRUCTIONS WITH HOME OWNER

TYPICAL INSTALLATIONS

Table of contents