Antari HZ-100 User Manual
Page 6
5
•Remote Control Operation
HC-1:10 meter wired multi-function remote controller with ¼” stereo plug.
Red: CONTROL ON/OFF
Green: HAZE
Yellow: TIMER ON/OFF
DURATION and INTERVAL knobs
Connect the unit to the mains; set the power switch on the at rear of the machine to
on. Press the red button (CONTROL ON/OFF), the red indicator light will be on at
the same time. This haze machine is ready to operate.
Keep the green button (HAZE) pressed; the unit will produce continuous haze output.
Release the button to stop output. During this time, the red button (CONTROL
ON/OFF) is kept pressed while the red indicator light is still on.
Press the yellow button (TIMER ON/OFF) to activate the timer function for the knobs
DURATION and INTERVAL located on the top of the controller. Adjust the interval
between each haze emission (within the range from 10 to 200 seconds) by means of
the INTERVAL control knob. Adjust the duration of each haze emission (within the
range of 5 to 100 seconds) by means of the DURATION control knob.
HCR-1: Wireless remote controller with ¼” stereo plug for Antari Hazer models HZ-100 /
HZ-300 and HZ-400. Attach the receiver’s magnetic base to the hazer. Plug the
receiver’s cable into the hazer’s remote control input. Using the sending unit,
your Antari Hazer can be operated from a distance at least 50 meters when
under no obstruction. Start haze emission by pressing the small button on the
sending unit. Stop haze emission by pressing the large button. Multiple Antari
Hazers may be controlled using only one sending unit.
*The control of the master unit will override all other controllers when connecting the
haze machine via DMX*
•DMX Connector Pin Assignment
The machine (HZ-300 , HZ-400) provide 3 or 5 pin XLR connector for DMX connection.
Diagram below indicate pin assignment information