INSTALLATION m (JOIST MOUNTING - II)
Joist situation:
Spacing B is
10
1/2
inches (266 mm) to
111/2 inches (292 mm)
on joists
1. If the spacing B is 10 1/2 inches (266 mm) to 11 1/2
inches (292 mm) on joists, please follow the
installation step as below.
2. Secure 4 long screws (ST 4.2X20) at flange of frame. (Fig.12)
3. Follow steps 4 to 10 of installation I (page
8
and page 9)
to complete the installation work.
MAINTENANCE (CLEANING)
WARNINS:
Disconnect power source before working on unit. Routine
maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2. Do not immerse motor in water when cleaning.
3. Do not soak resin parts in water over 140°F (60°C).
1. Remove grille pull down one mounting spring(no sensor
lead passed). Remove sensor unit then pull down the
other mounting spring. (Squeeze mounting spring and
pull down carefully). (Fig.13, Fig.14)
2. Clean grille. (Don't put into hot water. Use non-abrasive
kitchen detergent, wipe dry with clean cloth) (Fig. 15)
3. The grille should be dry after cleaning.
4. Remove dust and dirt from fan body using a vacuum
cleaner. (Fig. 16)
5. Using a cloth dampened with kitchen detergent, remove
any dirt from fan body. Wipe dry with clean cloth. (Fig. 17)
6
. Replace grille.
1 1
Ceiling
Fig.16