beautypg.com

Jaclo Faucet, Lavatory Faucet - 8880-T672 User Manual

Page 3

background image

jaclo

industries | 129 Dermody Street Cranford, NJ 07016

p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133

CREATED 8.6.2014

JACLO.COM | PG 3

FIGURE 5

HOT

COLD

Spout Installation

Note: Some items have been

pre-assembled at the factory to

ensure quality and fit. Some

disassembly may be required

during installation.

1. Remove nut (14), washer (13) and

"T" if installed from spout mounting

nipple (15).

2. Slide spout assembly through

counter top or basin.

3. Slide washer (13) onto spout nipple

install nut (14) onto spout nipple and

secure spout onto counter top or

basin once positioned correctly.

4. Install "T" (16) onto nipple (15) using

a NSF listed joint compound.

Valve Installation

1. Identify hot and cold valves. Hot

has red ring and cold has blue ring.

2. Install hot valve on left side of spout

when facing sink.

Figure 3

3. Install cold valve on right side of

spout when facing sink.

Figure 3.

4. Remove handle, escutcheon, and

top valve nut.

5. Adjust lower valve nut (10) down

away from valve stem.

Figure 4.

6. Place fiber washer (9) on top of nut.

7. Find handle/escutcheon "A"

dimension.

Figure 5.

8. Thread nut up towards stem so

distance from top of fiber washer to

top of valve stem= "A" dimension +

counter or basin thickness.

9. Install valve through bottom of

counter or basin.

Figure 4.

10. Install top nut and escutcheon on

to valve and tighten. *Note: not all

handle escutcheon combinations

use a top nut.

Figure 5.

11. Confirm "A" dimension for faucet

model installed. Adjust if necessary.

Hose Installation

1. Connect hot hose to hot valve outlet

and "T".

Figure 3.

2. Connect cold hose to cold valve

outlet and "T".

Figure 3.

3. Connect supply hoses or tubes

(not supplied) to base of hot and

cold valves.

Figure 4.

FIGURE 1

FIGURE 3

FIGURE 4

FIGURE 2

Valve Stem

Counter or

Basin

*No top nut used

on any of these

handles