8 | technical data – GEA Bock HА4 User Manual
Page 27

D
GB
F
E
I
Ru
27
09791-01.2015-DGbFEIRu
8| Technical data
Ty
pe
No. of cylinders
Displace
-
ment
50 / 60 Hz
(1450
/ 1740
rpm
)
Electrical data
W
eight
Connections
Oil charge
Sound
pressure
level
Voltage
Max.
Operating current
PW 1 + 2
Max.
power
consump
-
tion
Starting
current
(rotor
locked)
PW 1 / PW 1 + 2
Dis
-
charge
line
DV
Suction
line
SV
m
3
/h
A
kW
A
kg
mm (inch)
mm (inch)
Ltr
.
dB(A)
HA4/310-4
4
27,1 / 32,5
17
9,4
57 / 75
154
22 (
7
/
8
)
28 (1
1
/
8
)
3,4
70 / 69
HA4/385-4
33,5 / 40,2
21
11,6
82 / 107
152
HA4/465-4
40,5 / 48,6
21
11,2
82 / 107
155
28 (1
1
/
8
)
35 (1
3
/
8
)
HA4/555-4
48,2 / 57,8
26
13,3
107 / 140
157
HA4/650-4
56,6 / 67,9
26
15,6
107 / 140
156
1
2
3
2
4
380-420 V Y/YY - 3 - 50 Hz PW
440-480 V Y/YY - 3 - 60 Hz PW
PW = Part Winding
Winding ratio: 66% / 33%
L / M
5
Tolerance (± 10%) rela
tive to the mean value of the volta
ge range.
Other
volta
ges
and
types
of
current
on
request.
-
Th
e
sp
ec
ifi
ca
tio
ns
fo
r ma
x.
p
ow
er
c
on
su
m
pt
io
n
ap
pl
y
fo
r 5
0H
z
op
er
at
io
n.
Fo
r 6
0H
z
op
er
at
io
n,
th
e
sp
ec
ifi
ca
tio
ns
h
av
e
to
b
e
m
ul
tip
lie
d
by
th
e
fa
ct
or
1.
2. T
he ma
x. w
or
kin
g c
ur
re
nt r
ema
in
s u
nc
ha
ng
ed
.
-
Take account of the max.
opera
ting current / max.
po
wer consumption for
design of fuses,
supply lines and safety devices.
Fuse:
Consumption
ca
tegor
y AC3
1
2
All
specifica
tions
are
based
on
the
a
vera
ge
of
the
volta
ge
range
For solder connections
L = lo
w tempera
ture (-35 / 40 °C),
M
= normal cooling (-10 / 45
°C),
sound
pressure
level
measured
in
lo
w
reflection
measuring
area,
measuring distance 1m.
Compressor opera
tion a
t 50 Hz (1450 rpm),
refrigerant R404A.
Values
sta
ted
are
a
vera
ge
values,
tolerance
±
2
dB(A).