Audio Performance
Conditions: Unless otherwise specified, all measurements
are performed at 1 watt with a 1 kHz signal.
Line Inputs
Connectors: XLR Balanced
Frequency Response: 20 HZ - 20 kHz
Maximum Input Level: 15 dBu
Impedance: 10 KΩ
Outputs
Amplifier Output: 160-Watts/Channel into 8 Ω
Frequency Response: 20 HZ - 20 kHz
Channels: 4-Channel
Connectors: Binding Post or SpeakOn®
Impedance: 8 Ω
THD+N <.05% at 1 Watt
SMPTE IMD <.1% from 60 HZ to 7 kHz
Dynamic Range >100 dB
Damping Factor: 220
Crosstalk >65 dB
Protection Features
Thermal Shutdown
Current Limiting
Other
Bridgeable Outputs
Parallel or Stereo Impedance Switch
Clip, Presence, Fault Indicators
Front Panel Gain Controls
Front Panel On/Off Switch
CONVERGE
PA 4160
dATA SHEET
<
>
CONVERGE
PA 4160 BACK PANEL
>
SPECIFICATIONS
>
CLEARONE LOCATIONS
Headquarters:
Salt Lake City, UT USA
5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116
Tel: 801-975-7200
Toll Free: 800-945-7730
Fax: 801-977-0087
[email protected]
Latin America
Tel: 801-974-3621
[email protected]
EMEA
Tel: 44 (0) 1189 036 053
[email protected]
APAC
Tel: 801-303-3388
[email protected]
Other product names may be registered trademarks of their respective owners who do not necessarily endorse ClearOne or ClearOne’s products. All rights reserved. Information in this document subject to change without notice
.
© 2008 ClearOne Communications Inc. 802-151-960 Revision 1.0. June, 2008.
Power
910-151-960 (US Version)
120 VAC; 60 Hz, 5.0 Amp max
910-151-961 (EU Version)
240 VAC; 50 Hz 2.5 Amp max
Operating Temperature
75 C° ambient unit temperature
Humidity
15 to 80%
dimensions (L x d x H)
18.89” x 18.58” x 3.46” (2 RU)
47.98 x 47.19 x 8.78 cm
Weight
40.8 lbs/18.5 kg unit weight
Compliance
FCC Part 15 Subpart B
EN 55103-1 55103-2
EN 60065
RoHS
WEEE
Part Number
910-151-960 Converge PA 4160 (US Version)
910-151-961 Converge PA 4160 (EU Version)
Asia-Pacific Support Center
Tel: 852-3590-4526
[email protected]