beautypg.com

Checkline DT-329 User Manual

Page 7

background image

4

3.2 Operation panel
























No.

Key

Function Instructions

1

POWER

Power the unit on or off

2

MODE

Select Internal /External/Parameter mode of operation

3

SET

Unit change, Select parameter setting item, Store setting value.

4

×2

Multiplies the flash rate/frequency by a factor of 2.

5

1/2

Divides the flash rate/frequency by a factor of 2.

6

FLASH

Flash on and off

7

PHASE “+”

Advance image forwards 3 degrees at a time in internal mode.
In parameter setting mode, change setting value.

8

PHASE “-“

Retard image backwards 3 degree at a time in internal mode.
In parameter setting mode, change setting value.

9

Dial

Set flash rate or frequency.
CW; Increase flash rate/frequency.
CCW; Decrease flash rate/frequency.
(Turn dial “quickly” to drastically change value. Turn dial “slowly” to change value 1 digit.)
In parameter setting mode, CW or CCW rotating changes the setting value.

10

FOCUS

Adjusts the flash duration (flash pulse width) in Internal/External mode.