beautypg.com

Before you request a service call – Carrier ERVCCSVA User Manual

Page 3

background image

3

BEFORE YOU REQUEST

A SERVICE CALL

S

Check the main power disconnect switch. Verify that the
circuit breakers are ON or that fuses have not blown. If you

must reset breakers or replace fuses, do so only once. Contact
your servicing dealer for assistance if the breakers trip or the
fuses blow a second time.

S

Check for sufficient airflow. Check air filters for
accumulations of large particles. Check for blocked

exhaust--air grilles or ductwork. Keep grilles and duct work
open and unobstructed.

S

Check to see if the unit is calling for air exchange, or unit is in
defrost. When outdoor ambient temperature is below 23°F,

some degree of defrost mode is possible. Defrost length could
be 5 to 20 minutes, depending on temperature and settings.

If your ERV still fails to operate properly, contact your servicing
dealer. Give him your model and serial number. With this informa-

tion, the dealer will be able to correct any problems.

Table 2—Recommended Humidity Settings

OUTSIDE TEMPERATURE

DOUBLE---PANE WINDOWS

TRIPLE---PANE WINDOWS

50° F

10° C

55 percent

65 percent

32° F

0° C

45 percent

55 percent

14° F

---10° C

35 percent

45 percent

---4° F

---20° C

30 percent

45 percent

---22° F

---30° C

25 percent

35 percent

DOOR IS

DETACHABLE

FILTERS ARE

REMOVABLE BY

PULLING STRAIGHT

OUT

ENERGY RECOVERY

CORE CAN BE REMOVED

BY PULLING STRAIGHT OUT

BRIEF CASE

TYPE LATCH

A99300

Fig. 3 -- Horizontal Application

This manual is related to the following products: