4.0 Installation/Mounting
Mount the strobe in the desired location using the threaded inserts located on the
underside of the strobe housing (shown below). There are two (2) M5 metric threaded
inserts and one (1) 1/4-20 inch threaded insert. Use appropriated plate and screw to
attach to customer-supplied mounting fixture.
M5 Metric
Threaded Insert
M5 Metric
Threaded Insert
1/4 -20 Inch
Threaded Insert
– 8 –
D. Trigger signal from optional,
hand-operated stroboscope control
unit (e.g. RT Strobe control or
RT Strobe eco control), supply
voltage from optional AC adapter
(Fig. 5).
The power is either supplied by the LS-18-LED power supply unit (available as an
option) or the equipment being observed.
The LS-18-LED requires an external trigger source. Possible trigger sources include a
stroboscope control unit, an external machine or a sensor.
NOTE!
When using the stationary stroboscope without stroboscope control unit, the stroboscope
flashes with the trigger signal of the connected equipment. This signal cannot be