beautypg.com

Customization, Optimization and, Aes/ebu sample rate – AYRE QA-9 User Manual

Page 10

background image

Optimization and

Customization

While the Ayre QA-9 A/D is typically configured
with your recording software via the USB
connection, the AES/EBU settings and other options
are configured with small toggle switches accessible
on the rear of the unit.

AES/EBU Sample Rate

The AES/EBU output sample rate can be configured
as detailed in the table below:

4x/1x

2x/1x

48/44

Sample Rate

Down

Down

Down

44.1 kHz

Down

Down

Up

48.0 kHz

Down

Up

Down

88.2 kHz

Down

Up

Up

96.0 kHz

Up

Don’t Care

Down

176 kHz

Up

Don’t Care

Up

192 kHz

The AES/EBU output is only active
when there is no USB connection.