background image

Unbalanced Power Amplifiers

When using the Ayre K-1x

with an unbalanced power

amplifier, note tha t the

unity-gain volume setting will

now occur when the volume

control is five steps below the

maximum setting.

Unbalanced power amplifiers with single-ended inputs only
utilize one-half of the Ayre K-1x’s balanced output signal.
The result is a 6 dB gain reduction, requiring that the
volume control be further advanced for an equivalent
listening level. However, certain systems may have
insufficient gain to produce a satisfying listening level, even
with the volume control turned fully up.

If required, the gain of the line stage can be increased 6 dB
to compensate for this loss. Please contact your authorized
Ayre dealer or the factory for information on this
procedure. (It is not recommended to increase the gain of
the Ayre K-1x when using a balanced amplifier, as the level
of the lowest volume setting may be too loud.)

Break-In

Please note that the optional

phono stage utilizes

additional circuitry and will

require its own break-in

period.

A break-in period is required to achieve the maximum sonic
potential of the Ayre K-1x due to the manufacturing
processes used in the capacitors, circuit board material, and
wires. This normally requires between 100 and 500 hours of
playing time.