Troubleshooting

With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free ser-

vice. If you do experience a problem, this guide will assist a CERTIFIED SERVICE PERSON in the diag-

nosis of problems and the corrective action to be taken.

Symptom

Possible Causes

Corrective Action

Pilot will not light with piezo

ignitor or match

Pilot will not stay lit after care-

fully following lighting instruc-

tions

No gas to main burner with

pilot flame burning and valve

turned to “high - low” range

A. Main shutoff valve closed

B. Air in the gas line

C. Pilot orifice plugged, not allow-

ing gas to flow

D. No gas supply to the fireplace

A. Defective thermocouple

B. Thermocouple fitting not tight

in valve

C. Weak pilot flame

D. Defective valve

E. Not enough oxygen in the

room

(DANGER!)

A. Plugged main burner orifice

B. Defective valve

Make sure the shutoff valve

located on the gas supply line

is open

Light a match, turn valve knob

to “PILOT” position and de-

press. Keep match near pilot

burner until it lights

Replace the burner assembly

Check plumbing to see if gas

fireplace has been hooked up

to the gas supply line

Propane tank empty

Replace burner assembly

Carefully tighten fitting

Pilot flame must engulf ther-

mocouple. Clean and/or

adjust pilot for maximum flame

impingement on thermocouple.

(Fig. 14, 15)

Replace burner assembly

Open door and get fresh air at

once!

Replace burner assembly

Replace burner assembly