Windy Nation Xantrex Complete Charge Controller User Manual
Page 5
5
Setting
the
Voltage
and
Operating
Mode
Jumpers
for
the
Xantrex
C-‐Series
Charge
Controller
Windy
Nation
configured
the Voltage Jumper for the Xantrex C-‐Series Charge Controller at the factory.
(e.g.
12
volt
Xantrex
Complete
Charge
Controllers
have
been
set
for
12
volt
battery
bank
operation,
24
volt
Xantrex
Complete
Charge
Controllers
have
been
set
for
24
volt
battery
bank
operation,
and
48
volt
Xantrex
Complete
Charge
Controllers
have
been
set
for
48
volt
battery
bank
operation.)
WindyNation
has
also
configured
the Operating Mode Jumper at the factory. It has been set to Charge
Control
Mode
Jumper
which
is
the
appropriate
setting
for
operating
the
controller
in
Diversion
Mode.
Refer
to
page
20
of
the
Xantrex
C-‐Series
Owner’s
Manual
for
an
explanation
of
how
the
Xantrex
C-‐Series
Voltage
and
Operating
Mode
Jumpers
are
configured
to
operate
correctly.
Adjusting
the
Voltage
Settings
of
the
Xantrex
C-‐Series
Charge
Controller
WindyNation
has NOT set
the bulk and float voltage trip points on the Xantrex C-‐Series Charge
Controller. The reason this
is NOT
done by Windy Nation is because different battery types (e.g.
automotive
batteries,
maintenance
free
batteries,
deep
cycle
batteries,
sealed
batteries,
etc.)
require
different
charging
/discharging
voltage
levels.
Refer
to
pages
74-‐76
of
the
Xantrex
C-‐Series
Owner’s
Manual
and
contact
the
company
that
sold
you
the
batteries
or
the
manufacturer
of
the
batteries
to
find
out
the
appropriate
voltage
settings
(bulk
and
float)
for
your
particular
batteries.
Once
you
determine
the
appropriate
charging
(bulk
and
float)
voltage
settings
for
your
batteries,
refer
to
pages
4-‐5
and
pages
22-‐29
in
the
Xantrex
Owner’s
Manual
for
directions
on
how
to
set
the
bulk
and
float
voltage
settings
on
the
Xantrex
C-‐Series
Charge
Controller.
Grounding
the
Xantrex
Complete
Charge
Controller
Refer
to
page
37
of
the
Xantrex
Owner’s
Manual
for
instructions
on
how
to
properly
ground
the
Xantrex
C-‐Series
Charge
Controller.
Wiring
the
Xantrex
Complete
Charge
Controller
to
the
Renewable
Energy
(RE)
System
For
detailed
instructions
on
wiring
the
Xantrex
Charge
Controller,
refer
to
pages
38-‐43
and
46-‐47.
The
Windy
Nation
Xantrex
Complete
Charge
Controller
has
been
wired
in
Diversion
Mode
at
the
factory.
Refer
to
pages
46-‐47
of
the
Xantrex
Owner’s
Manual
for
a
detailed
description
of
the
Diversion
Mode
wiring
schematics.
After
reviewing
pages
46-‐47
of
the
Xantrex
Owner’s
Manual,
you
will
see
that
there
are
additional
wiring
steps
that
must
be
completed
to
safely
and
properly
connect
the
Xantrex
Complete
Charge
Controller
to
your
RE
system.
These
steps
are
listed
below
and
can
be
referred
to
on
pages
46-‐47
of
the
Xantrex
C-‐Series
Owner’s
Manual: