Applicable to models: cfd-1f, cfd-2f, cfd-3f, Coldtech® freezer settings – ColdTech CFD-2F User Manual
Page 10

ColdTech® Freezer Settings
Temperature set to -4 F
Parameter Function
Set Range
Default
E1
Lower Setpoint Limit
-40 F ~ set temp
-10 F
E2
Higher Setpoint Limit
set temp ~ 120 F
20 F
E3
Hysteresis, temp variance
1 ~ 18 F
10 F
E4
Comp. start delay time
0 ~ 10 min.
3 min.
E5
Offset on room temp
-5 ~ 5 F
0 F
E6
Offset on evap temp
-5 ~ 5 F
0 F
F1
Max. defrost duration
1 ~ 60 min.
30 min.
F2
Defrost interval time
0 ~ 24 hr.
6 hr.
F3
Defrost termination temp
32 ~ 68 F
68 F
Key
F = Farenheit (degrees)
temp = temperature
min. = minutes
max = maximum
hr. = hours
N/A = not applicable
Warning:
Do not change the default settings of your ColdTech unit
without consulting a qualified service technician or the
ColdTech service department.
-10-
Applicable to Models: CFD-1F, CFD-2F, CFD-3F