Operation - control panel – Caldera Paradise Series User Manual
Page 11

STANDARD OR ECONOMY MODE
When in ECONOMY mode, “ECON” flashes alternately
with the water temperature on the LCD. The heater oper-
ates only during skim/filter cycles to heat the spa water
with the following exception: Should the spa water tem-
perature fall below 20
0
F of set temperature, the heater will
engage to heat the spa water to within 15
0
F of the set
temperature.
In the STANDARD mode, “ECON” does not display on the
LCD.
The spa’s automatic operation is exactly as
described for ECONOMY mode except that the heater
and low-speed pump activate as needed to maintain the
set temperature between filter cycles.
SKIM/FILTER CYCLES
Your spa will automatically perform two skim/filter cycles
each day. At the beginning of each cycle, the single-
speed pump and the optional air blower turn on for brief
periods to ensure complete water circulation.
The dual-speed pump’s low speed operates for the entire
duration for which the filter cycle is set. Also, the option-
al ozone generator operates only during these cycles.
ADJUSTING THE SKIM/FILTER CYCLES
START TIMES The first cycle starts five to ten minutes
after the time of day when the power to your spa was last
turned on at the circuit breaker or GFCI. The second
cycle begins twelve hours later.
To change the start
times, simply turn the power to the spa off and back on at
the time of day you want the first cycle to begin.
DURATION The length of each filter cycle is factory pre-
set for two hours. You may adjust the cycle length with
this simple procedure:
1. Press either
or
, then press the
“HYDRO JETS 1” touch pad within three seconds. The
LCD will read “FIL” followed by a number indicating the
number of hours each cycle will last.
2. Press or to adjust. Choices are 2, 3,
4 and 5 hours.
3. Press the “HYDRO JETS 1” touch pad again to
return the LCD to the normal display.
In the STANDARD mode, “ECON” does not display on
the LCD. The spa’s automatic operation is exactly as
described for ECONOMY mode except that the heater
and low-speed pump activate as needed to maintain
the set temperature between filter cycles.