Technical Data
* applies for 100 % target reflectivity (white painted wall),
low ambient light, 25 ºC
** applies for 10 to 500 % target reflectivity, high ambient
light, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence
level of 95%. The maximum tolerance may deteriorate to
0.1 mm/m between 10 m to 30 m and to 0.20 mm/m for
distances above 30 m
**** applies for 100 % target reflectivity, background illumi-
nation of approximately 30'000 lux
Message Codes
If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
General
Typical Measuring Tolerance* ± 1.0 mm / ~1/16" ***
Maximum Measuring
Tolerance**
± 2.0 mm / 0.08 in ***
Range at Leica target plate
GZM26
100 m / 328 ft
Typical Range*
0.05-80 m / 230 ft
Range at unfavourable
condition ****
50 m / 164 ft
Smallest unit displayed
0.1 mm / 1/32 in
Power Range Technology
™
yes
Laser class
2
Laser type
635 nm, < 1 mW
Ø laser point
at distances
6 /30 / 60 mm
10 / 50 / 100 m
Protection class
IP54 (dust- and splash
water protected)
Autom. laser switch off
after 90 s
Autom. power switch-off
after 180 s
Battery durability (2 x AAA)
up to 5000 measure-
ments
Dimension (H x D x W)
114 x 50 x 27 mm
4.49 x 1.97 x 1.06 in
Weight (with batteries)
126 g / 4.05 oz
Temperature range:
- Storage
- Operation
-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F
Functions
Distance measuring
yes
Min/Max measuring
yes
Permanent measuring
yes
Stake-out
yes
Addition/Subtraction
yes
Area
yes
Volume
yes
Painter function (area with
partial measurem.)
yes
Pythagoras
2-point and 3-point
Memory
10 results
Beep
yes
Illuminated display
yes
Automatic multifunctional
endpiece
yes
No.
Cause
Correction
204
Calculation error
Perform measurement
again.
252
Temperature too high
Let device cool down.
253
Temperature too low
Warm device up.
255
Received signal too
weak, measuring time
too long
Change target surface
(e.g. white paper).
256
Received signal too high
Change target surface
(e.g. white paper).
257
Too much background
light
Shadow target area.
258
Measurement outside of
measuring range
Correct range.
260
Laser beam interrupted
Repeat measurement.