EMS Auxiliary Page
Available in 1/3 format
This is a customizable page where you may display up to six different info items. You may choose
from any of the available info items. For more information on configuring this display (as well as
info items on the EMS Main Page), see the Global Configuration Settings section on page 7-5.
Some info items, when displayed on the Aux Page, have quick commands in the AUX menu. This
menu is populated with commands in the order that the items appear on screen (from top left to
bottom right). The commands are listed below.
Info item quick commands
TIMERS info item – TRPRST (resets the trip timer), TIMER (shortcut to the general purpose
timer menu)
FUEL – FUEL (shortcut to the add fuel menu)
EMS Times Page
Available in 1/3 format
The Times Page is divided into three sections: TIME, TIMERS, and ENGINE TIMERS.
The TIME section shows the present time (both local and Zulu) and can be displayed in either
standard or military time formats.
The Flight Timer shows the total amount of time that oil pressure is above 15 PSI since the
EMS-D120 was turned on; it does not reset until the next time the EMS-D120 is power-cycled
and oil pressure reaches 15 PSI. The Trip Timer shows cumulative flight time since a manual
reset. The third line of this section contains the general purpose Timer which can be used for a
EMS-D120 Pilot’s User Guide
4-3