11. electrical service guide – Craftsman 117.205710 User Manual
Page 13
OM-194 199 Page 10
2-11. Electrical Service Guide
Input Voltage
200
230
Input Amperes At Rated Output
30
26
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Circuit Breaker
1
, Time-Delay
2
35
30
Normal Operating
3
45
40
Min Input Conductor Size In AWG/Kcmil
10
10
Max Recommended Input Conductor Length In Feet (Meters)
97
(29)
128
(39)
Min Grounding Conductor Size In AWG/Kcmil
10
10
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
Y
Caution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.
2-12. Selecting A Location And Connecting Input Power
1
Rating Label
Supply correct input power.
2
Plug
3
Receptacle
Connect plug to receptacle.
4
Input And Grounding
Conductors
Connect directly to line disconnect
device if hard wiring is required.
5
Line Disconnect Device
See Section 2-11.
Y
Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
Ref. 801 568 / Ref. 800 797-C
L1
L2
230 VAC, 1
18 in (457 mm) of
space for airflow
L1
L2
1
Y
Always connect grounding
conductor first.
= GND/PE
Y
Do not move or operate unit
where it could tip.
4
2
3
1
5