Calibrating the Humidity Display

1. Test the humidity display settings by placing the unit next to

another unit that is known to be accurate or by using the
Boveda One-Step Calibration Kit for at least 24 hours without

disturbing the environment

*

.

2. Determine the amount of calibration needed by taking the

display value and subtracting the expected value

**

. For

example, if you are expecting 70% but your unit displays 71%,

the amount of calibration needed is 71-70 = +1%.

3. Press the Set button for 3 seconds to place the unit into

calibration mode.

4. In calibration mode, you will see the current adjustment setting

flashing on the display. If this is the first time you are
calibrating your unit, it will show 0%. If you have already
calibrated the unit previously, you will see the current
adjustment.

5. Press the Min/Max/Clear button to adjust the display based

on your calibration. Pressing the button once will change the
adjustment by 1%. The adjustment range is +/-6% in the
following sequence: 0, +1, +2, +3, +4, +5, +6, -6, -5, -4, -3, -
2, -1, 0.

6. When you have completed your adjustment, press the Set

button one more time and it will take the unit out of
calibration mode. If you leave the unit in calibration mode for
more than one minute without pressing any buttons, the unit

will automatically will change back to operations mode.

* We recommend the Bovida One-Step Calibration Kit over other
testing methods. In no case do we recommend using the salt test.
This test is not accurate and can damage and void the warranty on
your Caliber IV

tm

.

** The Caliber IV

tm

can be adjusted +/- 6%. If you find the unit

is more than 6% out of calibration, please call us so that we can
troubleshoot with you or have you send it back for a factory
calibration.

Restoring Factory Calibration

To restore your Caliber IV

tm

back to factory calibration, simply

follow the calibration instructions above and adjust the display
back to 0%. This will restore the unit back to factory calibration.

Limited Warranty

The Caliber IV

tm

is covered by a limited warranty against defects

from materials or workmanship for a full 2 Years from the date of
purchase. Any misuse or excessive wear and tear is not covered
under the limited warranty. Keep your receipt in a secure location
as proof of purchase.

Contact Information

If you have any questions or warranty inquiries please call us
directly at 877-627-4798 or email [email protected].

Caliber IV

tm

is a trademark of

Western Humidor Corporation, USA

www.westernhumidor.com

And distributed by Cigar Oasis, Inc.

79 Heisser Court

Farmingdale, NY 11735

www.cigaroasis.com