beautypg.com

7 specifications – Crown CTS 4200 User Manual

Page 19

background image

page 19

CTs Multi-Channel Power Amplifiers

Operation Manual

7 Specifications

Figure 7.1

CTs 4200

Power Chart

Figure 7.2

CTs 8200

Power Chart

Channels Driven

2

4

1

2

1

1 kHz

20 Hz - 20 kHz

1 kHz

1 kHz

20 Hz - 20 kHz

4 Ohm

260

215

270

270

225

8 Ohm

200

190

210

220

210

70V ( 25 Ohm) at 0.1% THD

220

220*

240

250

245*

Channel Pairs Driven

1 kHz

20 Hz - 20 kHz

1 kHz

20 Hz - 20 kHz

520

430

560

450

400

380

440

420

220

220*

250

245*

8 Ohm
16 Ohm
100V (50 Ohm)

Bridge-Mono Mode

CTs 4200: MINIMUM GUARANTEED POWER

(in watts, 0.1% THD) 120VAC, 60 Hz units

Dual Mode

at 0.1% THD

* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.

Channel Pairs Driven

160

200

200

175
155
185*

250

190

220

260
200
240

270
220
250

230
220
230*

400

320
200

350
310
185*

540
440

250

460
440

230*

500
380

220

Bridge-Mono Mode

8 Ohm

16 Ohm
100V (50 Ohm) at 0.1% THD

70V (25 Ohm) at 0.1% THD

8 Ohm

4 Ohm

Channels Driven

Dual Mode

1 kHz

1 kHz

1 kHz

1 kHz

20 Hz - 20 kHz

1 kHz

20 Hz - 20 kHz

20 Hz - 20 kHz

1 kHz

1 kHz

20 Hz - 20 kHz

CTs 8200: MINIMUM GUARANTEED POWER

(In watts, 0.1% THD) 120VAC, 60 Hz units

8

4

2

1

4

2

1

* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.

This manual is related to the following products: