beautypg.com

Operation – Ryobi RY9904 User Manual

Page 11

background image

9 − English

OPERATION

GREEN

LED

RED

LED

ALARM

CONDITION

ACTION

Flash

The battery is charging.

Monitor battery until charging is
complete.

On

The battery is fully charged.

When charging is complete, the
maintainer will go into Float Mode.

ON

Beeps Continuously The battery’s polarity is reversed.

Reverse the position of the battery
cable’s clamps/rings on the battery’s
terminals.

Flash

Beeps Continuously

Battery or battery maintainer is
defective.

If defective, try to repeat the conditions
a second time by disconnecting and
reconnecting the battery charging
cables. If the LED status repeats a
second time, try charging a different
battery. If a different battery charges
normally, dispose of the defective
battery.

If a different battery also

indicates “Defective”, the maintainer
may be defective.

ELECTRONIC FEEDBACK

NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.

CHARGING

See Figures 6 - 7.

Ensure the voltage selector switch is in the off position.

Connect the battery maintainer to the power supply. Make

sure the power supply is normal household voltage, 120
volts, AC only, 60 Hz.

Attach battery charging cable to the battery maintainer

and then to the battery.

Slide the voltage selector switch to the appropriate

voltage setting.

Once charging begins, the green LED should start to flash.

NOTE: If the green LED does not flash or if the red LED
comes on, the battery is not charging properly. Turn
the battery maintainer off and refer to the

Electronic

Feedback section for solutions.

The battery will become slightly warm to the touch while

charging. This is normal and does not indicate a problem.

When charging is complete, the green LED will remain on

continuously. This indicates the battery is fully charged
and the maintainer is in Float Mode.

 The maintainer will periodically wake from Float Mode to

ensure the battery remains in a fully charged state.

When you remove the battery, disconnect the negative

(black) wire first, then the positive (red) wire, being careful
not to short across the terminals. Always abide by the
safety warnings provided with the battery.

NOTE:

It is highly recommended that you refer to your

battery manufacturer’s instructions for specific charge
times.

Unplug charging cable and store for later use.

NOTE: Place end cap onto the battery charging cable
when not in use.