beautypg.com

Operation maintenance, Evaluating, Charging – Ryobi P119 User Manual

Page 5: Charged

background image

5 − English

NOTE: ILLUSTRATIONS START ON PAGE 6

AFTER FRENCH AND SPANISH LANGUAGE SECTIONS

OPERATION

MAINTENANCE

WARNING:

When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.

WARNING:

To avoid serious personal injury, always remove the
battery pack from the tool when cleaning or performing
any maintenance.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.

WARNING:

Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which could result in serious personal
injury.

STORAGE

Always remove the battery pack before storing the charger
or any time the charger is unplugged.

This product has a Three-Year Limited Warranty.

Warranty details are available at www.ryobitools.com

MODE

LED

ACTION

Evaluating

Flashing

Battery is being tested. If voltage is low, battery is being conditioned and will begin charging when
normal voltage is reached. If battery is hot or cold, charger will begin charging when temperature
reaches an appropriate level.

Charging

Flashing

Battery is being charged.

Charged

On

Battery pack is fully charged and charger is in Energy Save mode.

• If charger indicates “Evaluate” for longer than 30 minutes at room temperature, battery pack may be defective. Try to repeat the

conditions a second time by removing and reintalling the battery pack. If the LED status repeats a second time, try charging a
different battery.

• If a different battery charges normally, dispose of the defective pack (see battery pack operator’s manual).
• If a different battery also indicates “Evaluate” for longer than 30 minutes, the charger may be defective.

LED FUNCTIONS