Troubleshooting maintenance, Warning, Symptoms probable cause corrective action – Night Optics Argus 740 4x Gen 3 Gated Night Vision Scope User Manual

Page 12

background image

11

NIGHT OPTICS USA

WEAPON SIGHTS

TROUBLESHOOTING

MAINTENANCE

!WARNING!

Improper care or unauthorized maintenance can damage device and may result

in warranty nullification.

Image dimmer than usual.

SYMPTOMS

PROBABLE CAUSE

CORRECTIVE ACTION

No visible Image

a. Objective lens cap not

been removed.

b. Battery cover is loose.

c. Incorrect battery polarity

d. Weak battery

a. Remove cap

b. Tighten cover

c. Reinsert battery

d. Replace battery

Image flickers, flashes, or

clicking is heard

a. Normal for new battery to

cause this for first five

minutes.

a. If condition continues

contact manufacturer for

service instructions

Dark spots on screen

a. Cosmetic blemishes.

Normal for this technology.

a. Acceptable as long as it

does not interfere with

operation of the device

Image not clear

a. Focus is not adjusted.

b. Too close to object

a. Adjust focus

b. Increase viewing distance.

Fixed pattern noise.

(honeycomb)

a. Cosmetic blemishes

caused by too much

illumination.

a. Acceptable as long as

target resolution can be

resolved.

Pattern of dark thin lines

(chicken wire)

a. Normal under worst

conditions. These lines will

form hexagonal or square

wave-shaved lines.
a. Weak batteries

b. Low natural illumination

level.

a. Acceptable as long as it

does not interfere with

operation of the device

a. Replace the batteries.

b. Turn on IR illuminator.