Cyclades PC400 User Manual
Page 23

23
Chapter 4 Board and System Configuration
Parameter
Description
Value for T1
line
Value for E1
line
unit_name
Name used to identify the board.
PC400
PC400
prompt
Can be changed to identify which board is being
accessed.
Select option
==>
Select option
==>
escape_char
0x1b is the
0x1b
0x1b
shortcut_char
0x0 turns this feature off.
0x0
0x0
username
Login name for administrator.
super
super
password
Password for administrator
supc
supc
syslog
Enables syslog messages indicated.
enabled
line|debug|user|s
ystem|modem
info
enabled
line|debug|user|s
ystem|modem
info
interf1_begin
First interface parameters
interf_type
Indicates line time
t1
e1
clock_mode
Normally slave.
slave
slave
line_code
There are two options each for T1 and E1 lines. Ask
the service provider.
b8zs
hdb3
frame_mode
There are several data framing options for both T1
and E1.
esf
crc4
line_build_out
Applies only to T1 lines. Ask the service provider.
0db
signaling_mode
Can be pri (ISDN), cas or none.
cas
cas
FIGURE 4.8 RAS DIAL-IN APPLICATION PARAMETERS