beautypg.com

Checking gas connections, Connecting to gas supply, Warning – Desa Tech CGP10T User Manual

Page 14: Caution

background image

14

102922

IMPORTANT:

Hold pressure regulator with wrench when connecting it to gas piping

and/or fittings.

Figure 13 - Gas Connection

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessory, page 28.

CHECKING

GAS

CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 Psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test

Gauge

Connection *

Heater
Cabinet

Pressure
Regulator

Tee

Joint

Pipe

Nipple

Cap

Ground Joint Union

3/8" NPT
Pipe Nipple

Sediment Trap

3" Minimum

Manual Shutoff Valve *

From External

Regulator

(11" W.C. to 14" W.C.

Pressure)

CONNECTING

TO GAS

SUPPLY

Continued

WARNING

Test all gas piping and connections for leaks after installation or
servicing. Correct all leaks at once.

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

CAUTION

Make sure external regulator has been installed between propane/LP
supply and heater. See guidelines under

Connecting to Gas Sup-

ply, page 13.