beautypg.com

Output characteristics – Zippy R3G-6650P User Manual

Page 11

background image

INPUT CHARACTERISTICS:

R3G-6650P

VOLTAGE: 90 ~ 264 VAC FULL RANGE

FREQUENCY : 47 ~ 63 Hz

INPUT CURRENT: 9.0 / 5.0 A FOR 115 / 230 VAC

INRUSH CURRENT: 80A / 100A MAX. FOR 115 / 230 VAC PER POWER MODULE

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN.[A] MAX.[A] PEAK(A)

LOAD

LINE

5V

3.0

60

±

5%

±

1%

50mV

12V

2

40

±

5%

±

1%

100mV

-5V

0.05

1

±

10%

±

1%

150mV

-12V

0.05 1

±

10%

±

1%

150mV

3.3V

1.0

40

±

5%

±

1%

50mV

+5VSB

0.1

2.5

±

5%

±

1%

50mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 70 A

TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 630 W

.

TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 70

0

C

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE

INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE

EFFICIENCY: 63% TYPICAL, AT FULL LOAD

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V

5.7V ~ 6.7V, 3.3V

3.7 ~ 4.7V, 12V

13.0 ~ 15.0V

. SHORT CIRCUIT : 5V,12V, 3.3V, AUTO-RECOVERED : 5VSB, -5V, -12V

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

REMOTE ON / OFF CONTROL

FAULTY ALERT METHODS : LED, BUZZER, TTL SIGNAL

2 + 1, HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION

N + 1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL

REMOTE SENSING DESIGN

ISOLATION: BUILT-IN IN THE POWER MODULE

MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )

DIMENSION: 82(H) X 127(W) X 276/300 (D) mm, 276mm -- W/O REAR DC FAN

COOLING : THREE 40 mm DC FANS ( ONE IN EACH MODULE )

ONE 80 mm DC FAN ( REAR SIDE )

Revision: A02