Output characteristics – Zippy R2Z-6400P User Manual
Page 5
1.6 SPECIFICATION
NPUT CHARACTERISTICS:
R2Z-6350/400P
l
VOLTAGE: 90 ~ 264 VAC FULL RANGE
l
FREQUENCY : 47 ~ 63 Hz
l
INPUT CURRENT: 8.0 / 5.0 A FOR 115 / 230 VAC
l
INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.[A] MAX.[A] PEAK(A)
LOAD
LINE
5V
3.0
25
± 5%
± 1%
50mV
12V
2
28
± 6%
± 1%
100mV
-5V
0.1
0.5
± 10%
± 1%
150mV
-12V
0.1
0.8
± 7%
± 1%
100mV
3.3V
1.0
20
± 5%
± 1%
50mV
+5VSB
0.1
2.0
± 5%
± 1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL POWER OF +5V AND + 3.3V NOT EXCEED 175W
TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 384 W
.
TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 70
0
C
l
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
l
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
l
EFFICIENCY: 65% TYPICAL, AT FULL LOAD
l
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l
OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V
à 5.7V ~ 6.7V, 3.3V à 3.7 ~ 4.7V, 12V à 13.0V ~ 15.0V
. SHORT CIRCUIT PROTECTION : SHUT DOWN
l
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
l
SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l
REMOTE ON / OFF CONTROL
l
FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
l
HOT-SWAPPABLE / HOT-PLUGGABLE 1 + 1 REDUNDANCY FUNCTION
l
BALANCE LOAD SHARING DESIGN
l
REMOTE SENSING DESIGN
l
ISOLATION: BUILT-IN IN THE POWER MODULE
l
MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )
l
DIMENSION: 84(H) X 101(W) X 265(D) mm ;
l
COOLING : TWO 38 mm DC FANS IN EACH MODULE