INPUT CHARACTERISTICS:
R2W-6500P
l
VOLTAGE: 100 ~ 240 VAC (WITH 5% TOLERANCE)
l
FREQUENCY : 47 ~ 63 Hz
l
INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC
l
INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.[A] MAX.[A] PEAK(A)
LOAD
LINE
5V
3.5
30
± 5%
± 1%
70mV
12V
2
32
± 5%
± 1%
120mV
-5V
0.05
0.7
+5/-10%
± 1%
120mV
-12V
0.05
0.7
+5/-10%
± 1%
120mV
3.3V
1.0
24
± 5%
± 1%
70mV
+5VSB
0.1
2.0
+ 6/-5%
± 1%
70mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 43 A;
total
output power not exceed 500w
.
TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 70
0
C
l
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
l
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1800 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1800 VAC FOR 1 MINUTE
l
EFFICIENCY: 67% TYPICAL, AT FULL LOAD 115V
l
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l
OVER LOAD PROTECTION: 110 ~ 170% MAX.
OVER VOLTAGE PROTECTION:
+5V
à 5.7V ~ 6.6V, 3.3V à 3.9 ~ 4.4V, 12V à 13.6 ~ 15.0V
. OVER CURRENT PROTECTION
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
l
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l
REMOTE ON / OFF CONTROL
l
FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
l
HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
l
REMOTE SENSING DESIGN
l
ISOLATION: BUILT-IN IN THE POWER MODULE
l
MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )
l
DIMENSION: 84(H) X 101(W) X 300 (D) mm
l
COOLING : TWO 38x38x28 mm DC FANS (MODULE)
l
AC INLET IN EACH MODULE