beautypg.com

Output characteristics – Zippy R2A-5350P User Manual

Page 7

background image

INPUT CHARACTERISTICS:

R2A-6350P

l

VOLTAGE: 90 ~ 264 VAC FULL RANGE

l

FREQUENCY : 47 ~ 63 Hz

l

INPUT CURRENT: 7.0 / 3.5 A FOR 115 / 230 VAC

l

INRUSH CURRENT: 50A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN.[A]

MAX.[A]

LOAD

LINE

5V

3.0

35

± 5%

± 1%

50mV

12V

2

8

± 7%

± 1%

120mV

-12V

0

0.8

± 10%

± 1%

150mV

3.3V

1.0

35

± 5%

± 1%

50mV

+5VSB

0.1

2

± 5%

± 1%

60mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 60 A

TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 330 W

.

TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 80

0

C

l

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE

l

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE

INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE

l

EFFICIENCY: 65% TYPICAL, AT FULL LOAD

l

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

l

OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V

à 5.7V ~ 6.5V, 3.3V à 3.9 ~ 4.3V, 12V à 13.6 ~ 15.0V

. OVER CURRENT PROTECTION : 5V, 3.3V 110% ~ 180% AT FULL LOAD
+12V, -12V SHORT CIRCUIT

l

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

l

SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

l

MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )

l

REMOTE ON / OFF CONTROL

l

FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL

l

HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION

l

BALANCE LOAD SHARING DESIGN

l

REMOTE SENSING DESIGN

l

ISOLATION: BUILT-IN IN THE POWER MODULE

l

MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)

l

DIMENSION: 85(H) X 120(W) X 220 (D) mm

l

COOLING : TWO 40 mm DC FANS PER MODULE

This manual is related to the following products: