Input characteristics: mrm-6600p, Output characteristics – Zippy MRM-6650P User Manual
Page 5
INPUT CHARACTERISTICS:
MRM-6600P
l
VOLTAGE: 90 ~ 264 VAC FULL RANGE
l
FREQUENCY : 47 ~ 63 Hz
l
INPUT CURRENT: 10 / 5 A FOR 115 / 230 VAC
l
INRUSH CURRENT: 80A / 150A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.[A]
MAX.[A] PEAK
LOAD
LINE
5V
1.0
28
+5% - 4%
± 1%
50mV
12V
2.0
45
+5% - 4%
± 1%
120mV
-5V
0
0.8
+5% - 8%
± 1%
120mV
-12V
0
1.0
+5% - 5%
± 1%
120mV
3.3V
1.0
28
+5% - 3%
± 1%
50mV
+5VSB
0.1
3.5
± 5%
± 1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL CURRENT OF +5V & +3.3V NOT EXCEED 45A, TOTAL MAXIMUM OUTPUT
OF 5V, 3.3V AND 12V: 572W
.
TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 80
0
C
l
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
l
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
l
EFFICIENCY: 68% TYPICAL, AT FULL LOAD
l
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l
OVER POWER PROTECTION: 110 ~ 150% MAX.
OVER VOLTAGE PROTECTION:
+5V
à 5.7V ~ 6.5V, 3.3V à 3.9V ~ 4.5V, 12V à 13.3V~ 14.5V
OVER CURRENT PROTECTION:100~150%
l
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
l
SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l
REMOTE ON / OFF CONTROL
l
FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
l
HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
l
BALANCE LOAD SHARING DESIGN
l
REMOTE SENSING DESIGN
l
ISOLATION: BUILT-IN IN THE POWER MODULE
l
MEET EN61000-3-2 CLASS D ( ACTIVE PFC )
l
DIMENSION: 84(H) X 150(W) X 254 (D) mm
l
COOLING:TWO 40 mm DC FANS (MODULE)
l
AC INLET IN EACH MODULE