Output characteristics, Specification – Zippy DR1M-6221F User Manual
Page 4
1.6 SPECIFICATION
INPUT CHARACTERISTICS:
DR1M-6220F
l
VOLTAGE: DC -36 V~ -72 V
l
INPUT CURRENT: 7.0 A ( RMS ) FOR -48VDC
l
INRUSH CURRENT: LESS THAN 10A FOR EACH MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
OUTPUT
VOLTAGE
MIN. [A]
MAX. [A]
LOAD
LINE
RIPPLE & NOISE
MAX. [P-P]
5V
3.0
25
±
5%
±
50mV
50mV
12V
2.0
16
±
5%
±
50mV
120mV
-5V
0
0.5
±
10%
±
50mV
150mV
-12V
0
0.5
±10%
±
50mV
150mV
3.3V
1.0
15
±
5%
±
50mV
50mV
+5VSB
0.1
2.0
±
5%
±
50mV
50mV
REMARKS:
1. THE OUTPUT POWER OF 5V & 3.3V MAX: 28A
SPECIFICATION:
l
TEMPERATURE RANGE: OPERATING: -10
--- 40
l
STORAGE: -20
--- 80
l
HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
l
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
l
EFFICIENCY: 68% TYPICAL AT -48VDC FULL LOAD
l
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms
l
OVER POWER PROTECTION: 110% ~ 160%
OVER VOLTAGE PROTECTION: +5V
à 5.7V ~ 6.6V, 3.3V à 3.9V ~ 4.8V
+12V
à 13.0V ~ 15.0V
l
SHORT CIRCUIT PROTECTION: +5V, +12V, +3.3V,AUTO-RECOVERED: 5VSB, -5V, -12V
l
EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
l
SAFETY: UL 60950, CSA 22.2 NO/ 60950, TÜV EN 60950, CB IEC60950.
l
REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE /
ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
l
FAULTY ALARM METHODS:LED, BUZZER,TTL SIGNAL.
l
HOT-SWAPPABLE/ HOT-PLUGGABLE 1+1 REDUNDANT FUNCTION.
l
BALANCE LOAD SHARING DESIGN.
l
ISOLATION:BUILT-IN THE POWER MODULE.
l
3.3V / 5V REMOTE SENSING
l
COOLING: TWO 40mm DC FAN (ONE IN EACH MODULE)
l
DIMENSION: 260 (D) x 180 (W) x 40.5 (H) mm
l
CONNECTOR POWER INPUT
A. POSITRONIC: PLB06M CONNECTOR
B. TERMINAL BLOCK