beautypg.com

Thetford Linear 170 Series User Manual

Page 9

background image

9

We recommend the underside of the hob be shielded particularly if this area is to be used for
storage or the installation of another appliance. The shield should be fabricated from
non-combustible material, but if the enclosure is manufactured from combustible material there
should be a minimum distance of 120mm between the worktop (top face) and the shield.
THIS AIR SPACE MUST BE WELL VENTILATED

On completion of the installation a warning notice complying to EN721 Annex A should be
affixed adjacent to the appliance.

If other appliance/s are located below the hob we recommend conducting a temperature
verification test to confirm any rise in temperature of the cabinet materials are within allowable
limits and meet requirements specified in EN30-1-1, EN1949, EN1645-1, EN1646-1, EN1647,
and EN721.

GAS CONNECTION
Prior to connection ensure the local conditions for gas type and gas pressure match the
appliance specification. (Gas type and pressure for this appliance are printed on the databadge
located on the base of appliance)

The Ø8mm gas inlet is located to the rear of the appliance. Prior to connection remove the
plastic protection plug from the fitting. The appliance MUST be connected using metal pipe
manufactured from either copper, seam welded steel, seamless steel or stainless steel, which
complies to the requirements of EN1949, rubber tubing MUST NOT be used.

ELECTRICAL CONNECTION
Spark Ignition
The spark ignition generator MUST only be connected to a suitable 12V DC supply. We
recommend connecting to the generator using sheathed spade connectors.

Electric Hotplate
The appliance must be connected using a double insulated cord, type 227 IEC 53, HO5V V-F,
which is suitable for use up to 4 amps. This should be connected to a double pole switched
mains supply, with 3mm minimum contact separation at all poles.

The supply cord MUST be retained using the attached cable clamp any excess cord MUST be
routed away from the appliance and not come into contact with the appliance or hang loose
into a lower compartment. See Fig. 3 for details of 240V electric circuit.







This appliance MUST be earthed

After Installation the appliance MUST be tested for tightness

The gas supply input pressure to which this appliance is connected,

MUST not rise or fall by more than 2.5 mbar (butane/propane) from
nominal when ALL appliances connected to the supply are OPERATED
simultaneously. If this appliance is not installed in accordance with the
instructions and tolerances detailed herein, we the manufacturer can not
be held responsible for any problems that occur, or poor performance
that is perceived/witnessed.


INSTALLATION