beautypg.com

Ignition - propane gas operation, Do a test of the gas safety valve, Start up - ac operation – Thetford N500 Series Owners Manual User Manual

Page 6: Start up - dc operation (n400.3 models), Shut down, Operating the refrigerator controls (n500 models), Control panel

background image

Owner’s Manual 6

Control panel:

Thermostat ........................................................................... 1
Selector switch ..................................................................... 2
Gas safety valve ................................................................... 3
Flame indicator .................................................................... 4

The thermostat [1] (See Art01281) changes the amount of
propane gas that goes to the burner. This acts as the tempera-
ture control of the refrigerator. Number 5 is the coldest tem-
perature setting.

When the outside air temperature is below 50° F, the refrigera-
tor may have a tendency to freeze food at the colder temperature
settings. To reduce the tendency to freeze food:

- Turn the thermostat to a warmer temperature setting.

- Keep the refrigerator full.

- Put foods that are more likely to freeze on the lower shelf.

The selector switch [2] changes the energy source of the

refrigerator between propane gas (

), AC electric (

), DC

electric (

), and OFF (

).

Operating the Refrigerator Controls
(N500 models)

Ignition - propane gas operation:

1. Open the valve at the propane gas storage tank.

2. Turn the thermostat [1] to the 5 position.

3. Turn the selector switch [2] to the propane gas position ( ).

4. Push and hold in the safety valve [4] and push in the igniter

[3] several times in rapid succession, for about five seconds:

WARNING:

Do not hold in the safety valve for more than

30 seconds. If there is no flame in this time, wait at least
five minutes before you try ignition again. If you continue
to hold in the safety valve, gas will collect in the burner
area. This could cause a fire or explosion and result in
dangerous personal injury or death.

- When a flame is present and the flame meter [5] moves into

the green area, wait about five seconds and release the
safety valve.

- If the flame meter does not move into the green area, do

this step again.

5. Turn the thermostat to the temperature setting that you wish.

Do a test of the gas safety valve:

With an established flame in GAS mode:

1. Close the manual gas shutoff valve [2] of the refrigerator

(See Art00975].

2. After the flame is extinguished, you should hear a sharp

“click” sound within three minutes.

NOTE: The gas safety valve should close with a sharp “click“

sound.

3. Open the manual gas shutoff valve of the refrigerator.

4. Without pushing in the gas control, push the igniter several

times rapidly in succession. The burner flame should not
ignite. This means that the gas safety valve is working
correctly.

Start up - AC operation:

- Make sure that 120 volts AC is available.

- Turn the selector switch to the AC position (

).

- Turn the thermostat to the temperature setting that you

wish.

Start up - DC operation (3-way model N400.3):

- Make sure that 12 volts DC is available.

- Turn the selector switch to the DC position (

).

Shut down:

- Turn the selector switch to the OFF position (

).