Do a test of the gas safety valve, Shut down – Thetford N1095 Series Installation Manual - 8/2/04 - 2/20/06 User Manual
Page 12
Installation Manual 12
2. Push the MODE button [2] until “AU” appears in center
display [4].
3. Push the TEMP SET button [3] as needed to set the thermo-
stat at “4-6” temperature setting.
- If “AU” “AC” appears in the center display, it means that:
- 120 volt AC power is available to the refrigerator.
- The refrigerator is operating on AC electric power.
- After ten seconds, the “AU” “AC” goes off and only a
green dot “.” remains to show that the refrigerator is
operating.
- If “AU” “LP” appears in the center display, it means that:
- 120 volt AC power is not available to the refrigerator.
- The refrigerator is operating on propane gas.
- After ten seconds, the “AU” “LP” goes off and only a
green dot “.” remains to show that the refrigerator is
operating.
Manual Mode Operation:
1. Push the ON/OFF button [1] to start the refrigerator.
2. Push the MODE button [2] until “LP” shows in the center
display [4].
3. Push the TEMP SET button [3] to set the thermostat at “4-6”
temperature setting.
4. The “LP” remains until you select a different operating mode
or shut down the refrigerator.
Do a test of the gas safety valve:
1. Start up the refrigerator in the manual mode operation.
2. Open the lower intake vent.
3. Remove one wire from the solenoid of the gas safety valve at
the rear of the refrigerator.
4. Within 30 seconds, the flame should extinguish. This
means that the gas safety valve is operating correctly.
5. Put the wire back on the solenoid of the gas safety valve.
6. Close the lower intake vent.
Shut down:
To shut down the refrigerator, push and hold the ON/OFF button
for two seconds.