beautypg.com

CLIFFORD Matrix 12 User Manual

Page 32

background image

27

© 2 0 0 6 d i r e c t e d e l e c t r o n i c s

the AED feature by turning the ignition key to the RUN

position and pressing the Valet button the programmed

number of times. AED is disabled when the system is in

Valet Mode.

Full trigger response 3

30

0 or 60 seconds: This determines how

long the full triggered sequence lasts. Some states have laws

regulating how long a security system can sound before it is

considered a nuisance. If your installer is programming the

security system with the Directed Bitwriter

®

, the full trig-

gered response can be programmed for any duration ranging

from 1 to 180 seconds.

Nuisance Prevention

®

Circuitry oon

n or off: Please refer to the

NPC

®

section of this manual for a complete explanation of

how NPC

®

operates. If NPC

®

is programmed off, the securi-

ty system will respond to inputs from any sensor indefinitely.

Progressive door trigger oon

n or off: When the system is armed

and a door is opened, the system responds with ten chirps

prior to beginning the full triggered sequence. If an instant

trigger is desired, the progressive door trigger can be pro-

grammed off.

note: Because many states have laws regulating security
systems, programming NPC

®

off may cause your system

to violate state laws.

note: This feature will only function if the Failsafe

®

Starter Kill relay has been installed.