PIN 4. SWITCH OUT

Connect to VCR trigger recording terminal of multiplexer, in order to synchronize

recording signals. The default mode is falling (Negative) Edge.

PIN 5. ERROR OUT

When HDD errors happen, this pin will send a signal out.

This pin become “Low” when HDD errors happen. The normal operation remains

“High”

PIN 6. REC START

This pin can accept the external trigger signal to activate record mode from

external device. When the external signal turn to “Low”, it will trigger DVR record

mode. When the external signal back to “High”, it will stop recording action.

The default normal operation remains “High”.

PIN 7. EXTERNAL ALARM NC

Under normal operation COM connect with NC and disconnect with NO. But when

alarm triggered, COM disconnect with NC, and connect with NO.

PIN 8. EXTERNAL ALARM NO

Under normal operation COM connect with NC and disconnect with NO. But when

Alarm triggered, COM disconnect with NC, and connect with NO.

PIN 9. GND

GROUND

PIN 10. RS485-B

DVR can be controlled remotely by an external device or control system, such as a

control keyboard, using RS485 serial communications signals.

PIN 11. RS485-A

DVR can be controlled remotely by an external device or control system, such as a

control keyboard, using RS485 serial communications signals.

PIN 12. DISK FULL

When HDD is full, it sends a signal to trigger next DVR record mode, if you install

another DVR. Under normal operation, the signal remains “High”. But when disk full,

DVR will send the “Low” signal.

PIN 13. ALARM RESET

To connect wire from ALARM RESET ( PIN 13 ) to GND ( PIN 9 ) connector, it can

disable ALARM. An external signal to ALARM RESET ( PIN 13 ) can be used to

reset both ALARM OUTPUT signal and DVR’s internal buzzer. When alarm has