beautypg.com

Symbology – Chicago Electric CHICAGO 9.5 AMP MAGNESIUM RECIPROCATING SAW 97580 User Manual

Page 8

background image

SKU 97580

For technical questions, please call 1-800-444-3353.

Page 8

the suffix “W-A” (“W” in Canada) to

indicate it is OK for outdoor use.

6. Make sure the extension cord is

properly wired and in good electrical

condition. Always replace a damaged

extension cord or have it repaired by

a qualified electrician before using it.

7. Protect the extension cords from

sharp objects, excessive heat, and

damp or wet areas.

RECOMMENDED MINIMUM WIRE

GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

AMPERES

(at full load)

EXTENSION CORD

LENGTH

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)