MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE,
continued
PROBLEM POSSIBLE
CAUSE
SOLUTION
Cabinet does not heat, or
doesn’t heat properly
1. Thermostat
2. Heater relay
3. Loose wiring at heater relay
4. Hi-limit switch
5. On/Off switch
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
Blowers do not operate
1. On/Off Switch
2. Blower
1. Replace
2. Replace
Heater will not shut off 1.
Thermostat
2. Relay
1. Replace
2. Replace
Vent fan does not shut off 1. Vent fan switch
2. Control compartment still hot
1. Replace
2. Wait until it cools
Check “Heaters will not shutoff”
Vent fan does not operate
(See Note)
1. Vent fan switch
2. Vent fan
1. Replace
2. Replace
NOTE:
Vent fans will not operate until the control compartment requires ventilation to limit
temperatures. Replacement of electrical components must be done by a qualified electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service
centers. Instructions for replacing parts are included in replacement parts list.
REPLACEMENT PARTS:
Include all information on nameplate when ordering parts.
Cabinet Replacement Parts
MODEL PREFIX CO-151
DESCRIPTION
-XUA5B -X185B
Hot Unit, 120V, 1 Ph
HU675045
HU675046
Door Latch Kit
1006-120-01
1006-120-01
Latch Strike
1006-120-02
1006-120-02
Door Hinge
0519-074
0519-074
Door Assembly
1221-545
1221-546
Door Gasket
0861-250
0861-251
Interior
0621-281
1104-107
Casters 0569-310
0569-310
Casters w/brake
0569-310B
0569-310B