Contec SEH-9450-LAS User Manual
Page 34

4. Jumper Setting
SEH-9450-LAS
27
Setting the RS-422/RS-485 receiver disable control jumper
When the RS-422/RS-485 port is used, the RTS signal is used for driver enable control Connecting
JCOM1 Pins 14 and 16 disables the receiver at the same time, preventing the port from receiving output
data to an external device.
RS-422/485 setting
RTS#
R
D
1ΚΩ
JCOM1: 14-6
JCOM1: 15-6
SOUTB
6.2ΚΩ
6.2ΚΩ
4.7KΩ
4.7KΩ 4.7KΩ
4.7KΩ 4.7KΩ
4.7KΩ
10 5
6 1
Figure 4.1.
RS-422/485 Setting
I/O addresses and instructions
The table below lists I/O addresses for use as SERIAL2.
Table 4.5.
I/O Addresses and instructions
I/O address
DLAB
Read/Write
Register
W Transmitter
holding
Register THR
0
R
Receiver buffer Register
RBR
02F8H
1
W
Divisor latch Register (LSB)
DLL
1
W
Divisor latch Register (MSB)
DLM
02F9H
0
W
Interrupt enable Register
IER
02FAH X
R Interrupt
ID
Register
IIR
02FBH
X
W
Line control Register
LCR
02FCH
X
W
Modem Control Register
MCR
02FDH
X
R
Line status Register
LSR
02FEH X
R Modem
Status
Register
MSR
02FFH X R/W
Scratch
Register
SCR