DESCRIPTION OF COMPONENTS:
RINSE SWITCH.
With the door open, the rinse switch is located on the left side of the first Whipper Chamber next to the power switch.
In the RINSE position it disengages the hopper motors and allows only water to be dispensed.
It is used for flushing out the Whipper Chambers and to adjust the water dispense valves for proper flow rates.
HEATER SWITCH.
This switch is located behind the cabinet in the rear of the unit.. Its primary function is to shut off the heating element
during the initial priming, start up operation of the machine, or whenever the tank is being drained for service.
Note: Power Switch and Heater Switch must be ON in order for the elements to operate.
POWER SWITCH.
With the door open, the power switch is located on the left side of the first Whipper Chamber next to the Rinse Switch. The
Power Switch controls all power to the machine including the heater elements.
WATER LEVEL CONTROLS.
Under normal conditions and operation, the water level in the tank should not drop more than ½" from the probe. If it does,
the tank is not refilling fast enough. Check the water line and water filter, they may need cleaning or replacing.
Mechanical Specifications
Model #
Label
No. of
Hoppers
Hopper
Capacity (lb.)
Width
(in.)
Depth
(in.)
Height
(in.)
Tank
(Gal.)
GB1CP
Cappuccino
1
8 lb.
7.75
19
27
2
GB2CP
Cappuccino
2
4 lb.
7.75
19
27
2
GB3CP
Cappuccino
3
4 lb.
9.88
19
27
2
GB1HC-CP
Hot Chocolate
1
8 lb.
7.75
19
27
2
GB2HC-CP
Hot Chocolate
2
4 lb.
7.75
19
27
2
GB1HC-CP-PC
Hot Chocolate
1
8 lb.
7.75
19
27
2
GB2HC-CP-PC
Hot Chocolate
2
4 lb.
7.75
19
27
2
Add an additional 2.5” when installing with legs. Add 2" for line cord and valve fitting clearance.
Plumbing: ¼” water line required.
Electrical Specifications
Model No.
Volts
Phase
Hz
Watts
Number of
Heaters
Amps
Receptacle
Nema No.
Circuit
Breaker
GB1CP, GB2CP, GB3CP
GB1HC-CP, GB2HC-CP
GB1HC-CP-PC*,•GB2HC-CP-PC*
120V
1
50/60 1.8KW
1
15
5-15R
15A
* Automatic Portion Control
For Wiring, refer to Wiring Diagrams.
See Electrical Data Label attached to the back of the unit for proper voltages, breaker sizes