beautypg.com

Product specifications, Unpacking, Operating instructions – Chicago Electric Battery Charger with LCD Display 65834 User Manual

Page 6: Symbology

background image

SKU 65834

For technical questions, please call 1-800-444-3353.

Page 6

least the minimum wire size required.

(See Table A.)
If you are using one extension cord

5.

for more than one tool, add the

nameplate

amperes and use the sum

to determine the required minimum

cord size.

(See Table A.)

Make sure the extension cord is prop-

6.

erly wired and in good electrical con-

dition. Always replace a damaged

extension cord or have it repaired by

a qualified electrician before using.

RECOmmEnDED mInImum WIRE

GAuGE FOR ExTEnSIOn CORDS*

(120 VOLT)

nAmEPLATE

AmPERES

(at full load)

ExTEnSIOn CORD

LEnGTH

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

PRODuCT SPECIFICATIOnS

Electrical

Requirements

120 VAC / 60 Hz

Power Cord: 18 AWG x 3C SVT

Power Plug: 3-Prong, Non-Polarized

Output Voltage: 14.4VDC Maximum

Output Current: 6 Amps Maximum

Product

Applications

6VDC or 12VDC Lead-Acid Batteries Only.

(3Ah to 48Ah Charger Capacity)

Indoor Use Only

Features

Three Error Codes Display:

“E01” = Wrong Polarity

“E02” = Disconnected During Charging

“E03” = Damaged Battery or

Not a 6V or 12V Battery

Battery Status Display:

Empty = No Battery/No Connection

One Bar = Battery Connected

Four Bars = Fully Charged

Flashing Bars = Battery Charging

4-Stage Charging Symbol Indicates

2 Amp, 4 Amp, 6 Amp, or Auto

Push Button Starts Charging

Display Shows Charging Voltage

Accessories

Battery Cable Clamps (Qty. 2)

unPACKInG

When unpacking, check to make sure

that the item is intact and undamaged. If

any parts are missing or broken, please

call Harbor Freight Tools at the number

shown on the cover of this manual as soon

as possible.

OPERATInG InSTRuCTIOnS

Read the EnTIRE ImPORTAnT

SAFETY InFORmATIOn section

at the beginning of this manual

before set up or use of this

product.

TO PREVEnT

SERIOuS InJuRY FROm ACCIDEnTAL

OPERATIOn:

unplug the Battery Charger from its

power source before performing any

inspection, maintenance, or cleaning

procedures.

SYmBOLOGY

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)